Features:
Horsepower .............. 00040.00 ~ KW: 29.84
Enclosure ............... TEFC
Poles ................... 06 ~ RPM: 1200
Frame Size .............. 364~T
Phase/Frequency/Voltage.. 3~060~230/460 ~ Random Wound
Service Factor .......... 1.00
Insulation Class ........ Class "H" ~ Insulife 2000
Altitude In Feet (Max) .. 3300 Ft.(1000 M)
Ambient In Degree C (Max) +40 C
Assembly Position ....... "F-1" Assembly Position
Efficiency Class ........ Premium Efficiency
Application ............. Unknown
Customer Part Number ....
Inverter Duty Rating:
Load Type (Base Hz & Below) .. Constant Torque
Constant HP Above Base Hz
Speed Range (Base Hz & Below). 20:1
1:1.5 Above Base Hz
"AK" Dimension (Inches).. NA
Temperature Rise (Sine Wave): "F" Rise @ 1.0 SF (Resist)
Starting Method ......... Direct-On-Line Start
Duty Cycle .............. Continuous Duty
Efficiency Value ........ 93.0 % ~ Typical
Load Inertia (lb-ft2): NEMA ~ NEMA Inertia: 503.00 ~ 1.00
Number Of Starts Per Hour: NEMA
Motor Type Code ......... CTI
Rotor Inertia (LB-FT²) 20.6 LB-FT²
Qty. of Bearings PE (Shaft) 1
Qty. of Bearings SE (OPP) 1
Bearing Number PE (Shaft) 6313-2Z-J/C3
Bearing Number SE (OPP) 6313-2Z-J/C3

 
NIDEC MOTOR CORPORATION
8050 WEST FLORISSANT AVE.
ST. LOUIS, MO 63136
U.S. Motors
 
DATE: 5/4/2024P.O. NO.:  FJ56
  Order/Line NO.: 23880  MN  100
TO: 
 
Model Number: FJ56
Catalog Number: H40T3B
 Hostile Duty VFD Duty Config.
 CONF,MOTOR,HOSTILE DUTY VFD DU
REVISIONS:
(NONE) 
 
ALL DOCUMENTS HEREIN ARE CONSIDERED CERTIFIED BY NIDEC MOTOR CORPORATION.
THANK YOU FOR YOUR ORDER AND THE OPPORTUNITY TO SERVE YOU.
Accessories:
Special Bearings
Special Balance
Thermostats - Normally Closed
Conduit Box Information: ~ Std. Oversized- Std. Const.
Conduit Opening Size (AA) .. 3" NPT
1 Conduit Opening ~ Bottom Of Conduit Box
Standard Leadtime: NA
Est. Weight (lbs ea): 740 ~ F.O.B.:
 
USE THE DATA PROVIDED BELOW TO SELECT THE APPROPRIATE DIMENSION PRINT
 
Horsepower 40
Pole(s) 06
Voltage(s) 460-230
Frame Size 364T
Shaft U Diameter 2.375
Outlet Box AF 3.38
Outlet Box AA 3