NIDEC MOTOR CORPORATION
8050 WEST FLORISSANT AVE.
ST. LOUIS, MO 63136
U.S. Motors
 
DATE: 3/29/2024P.O. NO.:  GM17
  Order/Line NO.: 26355  MN  100
TO: 
 
Model Number: GM17
Catalog Number: CVW15V3B6
REVISIONS:
(NONE) 
 
ALL DOCUMENTS HEREIN ARE CONSIDERED CERTIFIED BY NIDEC MOTOR CORPORATION.
THANK YOU FOR YOUR ORDER AND THE OPPORTUNITY TO SERVE YOU.
Features:
Horsepower .............. 00015.00 ~ KW: 11.19
Enclosure ............... TEAO
Air-Over Velocity (FPM).. 650
Poles ................... 06 ~ RPM: 1200
Frame Size .............. 284~T
Phase/Frequency/Voltage.. 3~060~230/460
Winding Type ............ Random Wound
Service Factor .......... 1.15
Insulation Class ........ Class "F" ~ Insulife 2000
Altitude In Feet (Max) .. 3300 Ft.(1000 M)
Ambient In Degree C (Max) +40 C
Assembly Position ....... "W-6" Assembly Position
Efficiency Class ........ Premium Efficiency
Application ............. Cooling Tower Duty
Inverter Duty NEMA MG1 Part 31
Customer Part Number ....
Inverter Duty Rating Details:
Load Type (Base Hz & Below) .. Variable Torque
Speed Range (Base Hz & Below). 20:1
VFD Service Factor 1.00
"AK" Dimension (Inches).. NA
Temperature Rise (Sine Wave): "F" Rise @ SF (Resist)
Design Letter ........... B
Starting Method ......... Direct-On-Line Start
Duty Cycle .............. Continuous Duty
Efficiency Value ........ 91.7 % ~ Typical
Load Inertia: NEMA ~ Standard Inertia: 200 LB-FT2
Number Of Starts Per Hour: NEMA
Motor Type Code ......... TCNI
Rotor Inertia (LB-FT²) 6.23 LB-FT²
Qty. of Bearings PE (Shaft) 1
Qty. of Bearings SE (OPP) 1
Bearing Number PE (Shaft) 6310-2RS-J/C3
Bearing Number SE (OPP) 6210-2RS-J/C3

 
NIDEC MOTOR CORPORATION
8050 WEST FLORISSANT AVE.
ST. LOUIS, MO 63136
U.S. Motors
 
DATE: 3/29/2024P.O. NO.:  GM17
  Order/Line NO.: 26355  MN  100
TO: 
 
Model Number: GM17
Catalog Number: CVW15V3B6
REVISIONS:
(NONE) 
 
ALL DOCUMENTS HEREIN ARE CONSIDERED CERTIFIED BY NIDEC MOTOR CORPORATION.
THANK YOU FOR YOUR ORDER AND THE OPPORTUNITY TO SERVE YOU.
Accessories:
Additional Stamping On Std N/P
Bearing Caps
Stainless Steel T-Drains-Pulle
Corro-Duty
Double Sealed Bearings
Horiz & Vert Lifting Lugs
115 Volt Space Heaters
Special Balance
Special Features Plate
Sealant on Registers
Internal Dolph Treatment for
Conduit Box Information: ~ Std. Oversized- Std. Const.
Conduit Opening Size (AA) .. 1.5" NPT
1 Conduit Opening ~ Bottom Of Conduit Box
Lead Positioning Gasket
Plastic Breather/Drain In
Special Features Plate Info:
COOLING TOWER DUTY
TEAO_650_FPM AIR
Stamp Following On Main N/P:
22ALDEABCB
Standard Leadtime: NA
F.O.B.:
~
~
 
USE THE DATA PROVIDED BELOW TO SELECT THE APPROPRIATE DIMENSION PRINT
 
Horsepower 15
Pole(s) 06
Voltage(s) 460-230
Frame Size 284T
Shaft U Diameter 1.875
Outlet Box AF 3.25
Outlet Box AA 1.5