NIDEC MOTOR CORPORATION
8050 WEST FLORISSANT AVE.
ST. LOUIS, MO 63136
U.S. Motors
 
DATE: 4/25/2024P.O. NO.:  HF43
  Order/Line NO.: 26921  MN  100
TO: 
 
Model Number: HF43
Catalog Number: HO100P2RLG
 VHS Weather Protected
 CONF,MOTOR,VHS WPI
REVISIONS:
(NONE) 
 
ALL DOCUMENTS HEREIN ARE CONSIDERED CERTIFIED BY NIDEC MOTOR CORPORATION.
THANK YOU FOR YOUR ORDER AND THE OPPORTUNITY TO SERVE YOU.
Features:
Horsepower .............. 00100.00~00000.00 ~ KW: 74.6
Enclosure ............... WPI
Poles ................... 04~00 ~ RPM: 1800~0
Frame Size .............. 404~TP
Phase/Frequency/Voltage.. 3~060~220/380/440
Winding Type ............ Random Wound
Service Factor .......... 1.15
Insulation Class ........ Class "F" ~ Insulife 1000
Altitude In Feet (Max) .. 3300 Ft.(1000 M) ~ +50 C
Efficiency Class ........ Premium Efficiency
Application ............. Vertical Centrifugal Pump
Customer Part Number ....
16.5" Base ~ Coupling Size: 1-3/16" Bore, 1/4" Key
Non-Reverse Ratchet ~ Steady Bushing Not Requested
Pricebook Thrust Value (lbs).. 6700
Customer Down Thrust (lbs) ... 6700
Customer Shutoff Thrust (lbs).
Up Thrust (lbs): ~
Temperature Rise (Sine Wave): "B" Rise @ 1.0 SF (Resist)
Starting Method ......... Wye Start-Delta Run & PWS
Duty Cycle .............. Continuous Duty
Efficiency Value ........ 95.4 % ~ Typical
Load Inertia: NEMA ~ Standard Inertia: 441.00 LB-FT2
Number Of Starts Per Hour: NEMA
Motor Type Code ............ RUS
Rotor Inertia (LB-FT²) 17.8 LB-FT²
Qty. of Bearings PE (Shaft) 1
Qty. of Bearings SE (OPP) 1
Bearing Number PE (Shaft) 6212-J
Bearing Number SE (OPP) 7222 BEM

 
NIDEC MOTOR CORPORATION
8050 WEST FLORISSANT AVE.
ST. LOUIS, MO 63136
U.S. Motors
 
DATE: 4/25/2024P.O. NO.:  HF43
  Order/Line NO.: 26921  MN  100
TO: 
 
Model Number: HF43
Catalog Number: HO100P2RLG
 VHS Weather Protected
 CONF,MOTOR,VHS WPI
REVISIONS:
(NONE) 
 
ALL DOCUMENTS HEREIN ARE CONSIDERED CERTIFIED BY NIDEC MOTOR CORPORATION.
THANK YOU FOR YOUR ORDER AND THE OPPORTUNITY TO SERVE YOU.
Accessories:
Shaft Slinger - Pulley End
CCW Rot. FODE w/Rotation Arrow
230 Volt Space Heaters
Synthetic Lubrication
Grounding Tag
Conduit Box Information: ~ Std. Oversized- Std. Const.
Conduit Opening Size (AA) .. 3" NPT
1 Conduit Opening ~ Bottom Of Conduit Box
Stamp Following On Main N/P:
74.6 KW IE3=95.4%
Standard Leadtime: NA
F.O.B.:
 
USE THE DATA PROVIDED BELOW TO SELECT THE APPROPRIATE DIMENSION PRINT
 
Horsepower 100
Pole(s) 04
Voltage(s) 440-220-380
Frame Size 404TP
Outlet Box AF 4.25
Outlet Box AA 3