DATE: | 5/17/2024 | P.O. NO.: | HT42 |
| | Order/Line NO.: | 27957 MN 100 |
TO: | | |
|
Model Number: | HT42 | Catalog Number: | CNT10P2EE |
| REVISIONS: (NONE) |
|
ALL DOCUMENTS HEREIN ARE CONSIDERED CERTIFIED BY NIDEC MOTOR CORPORATION. |
THANK YOU FOR YOUR ORDER AND THE OPPORTUNITY TO SERVE YOU. |
Features: |
Horsepower .............. 00010.00~00000.00 ~ KW: 7.46 |
Enclosure ............... TEFC |
Poles ................... 04~00 ~ RPM: 1800~0 |
Frame Size .............. 215~HP |
Phase/Frequency/Voltage.. 3~060~230/460 (Usable at 208V) |
Winding Type ............ Random Wound |
Service Factor .......... 1.15 |
Insulation Class ........ Class "F" ~ Insulife 2000 |
Altitude In Feet (Max) .. 3300 Ft.(1000 M) |
Ambient In Degree C (Max) +40 C |
Efficiency Class ........ Premium Efficiency |
Application ............. Centrifugal Pump |
Customer Part Number .... |
Base Diameter (Inches) ....... 10 |
Pricebook Thrust Value (lbs).. 640 |
Customer Down Thrust (lbs) ... 640 |
Customer Shutoff Thrust (lbs). |
Up Thrust (lbs): ~ |
Secondary Rating: |
10 Horsepower ~ 50 Hertz ~ 200/400 Volts |
"AK" Dimension (Inches).. NA |
Shaft Dimensions:~U=1.125 ~ AH/V=2.750 |
KEYWAY=0.250 ~ ES=1.280 |
Temperature Rise (Sine Wave): "B" Rise @ 1.0 SF (Resist) |
Design Letter ........... B |
Starting Method ......... Direct-On-Line Start |
Duty Cycle .............. Continuous Duty |
Efficiency Value ........ 91.7 % ~ Typical |
Load Inertia: NEMA ~ Standard Inertia: 51 LB-FT2 |
Number Of Starts Per Hour: NEMA |
Motor Type Code ............ TVCS |
Rotor Inertia (LB-FT²) | .967 LB-FT² |
|
Qty. of Bearings PE (Shaft) | 1 |
|
Qty. of Bearings SE (OPP) | 1 |
|
Bearing Number PE (Shaft) | 6309-J/C3 |
|
Bearing Number SE (OPP) | 6208-J/C3 |
|