MODEL NO. | CATALOG NO. | PHASE | TYPE | FRAME |
DX08 | CNT10P2DE | 3 | TVCS | 215HP |
ORDER NO. | 23159 | LINE NO. |
MPI: | 224590 | 224591 | 224592 | 224593 | 224594 |
HP: | 10 | 10 | 10 | 10 | 10 |
POLES: | 4 | 4 | 4 | 4 | 4 |
VOLTS: | 460 | 230 | 208 | 380 | 190 |
HZ: | 60 | 60 | 60 | 50 | 50 |
SERVICE FACTOR: | 1.15 | 1.15 | 1.15 | 1.15 | 1.15 |
EFFICIENCY (%): | |||||
S.F. | 90.8 | 90.8 | 88.8 | 85.9 | 85.9 |
FULL | 91.7 | 91.7 | 90.2 | 88.8 | 88.8 |
3/4 | 92.6 | 92.6 | 92.1 | 91.4 | 91.4 |
1/2 | 92.3 | 92.3 | 92.5 | 92.3 | 92.3 |
1/4 | 88.7 | 88.7 | 89.9 | 90.4 | 90.4 |
POWER FACTOR (%): | |||||
S.F. | 86.3 | 86.3 | 86.6 | 87 | 87 |
FULL | 85.4 | 85.4 | 86.6 | 86.8 | 86.8 |
3/4 | 82.2 | 82.2 | 85 | 85 | 85 |
1/2 | 74.7 | 74.7 | 80.2 | 79.3 | 79.3 |
1/4 | 54.1 | 54.1 | 62.9 | 61.1 | 61.1 |
NO LOAD | 6.1 | 6.1 | 6.7 | 5.7 | 5.7 |
LOCKED ROTOR | 45.1 | 45.1 | 44.2 | 47.3 | 47.3 |
AMPS: | |||||
S.F. | 13.7 | 27.5 | 31 | 17.4 | 35 |
FULL | 12 | 23.9 | 26.5 | 14.7 | 29.4 |
3/4 | 9.2 | 18.5 | 19.8 | 11 | 21.9 |
1/2 | 6.8 | 13.6 | 14 | 7.7 | 15.5 |
1/4 | 4.9 | 9.8 | 9.1 | 5.1 | 10.3 |
NO LOAD | 4.1 | 8.1 | 6.9 | 4 | 8 |
LOCKED ROTOR | 80 | 160 | 139 | 75 | 150 |
NEMA CODE LETTER | H | H | F | E | E |
NEMA DESIGN LETTER | B | B | B | B | B |
FULL LOAD RPM | 1760 | 1760 | 1750 | 1445 | 1445 |
NEMA NOMINAL / EFFICIENCY (%) | 91.7 | 91.7 | 90.2 | 88.8 | 88.8 |
GUARANTEED EFFICIENCY (%) | 90.2 | 90.2 | 88.5 | 86.5 | 86.5 |
MAX KVAR | 2.8 | 2.7 | 2.1 | 2.2 | 2.2 |
AMBIENT (°C) | 40 | 40 | 40 | 40 | 40 |
ALTITUDE (FASL) | 3300 | 3300 | 3300 | 3300 | 3300 |
SAFE STALL TIME-HOT (SEC) | 20 | 20 | 28 | 23 | 23 |
SOUND PRESSURE (DBA @ 1M) | 65 | 65 | 65 | 61 | 61 |
TORQUES: | |||||
BREAKDOWN{% F.L.} | 297 | 297 | 233 | 233 | 233 |
LOCKED ROTOR{% F.L.} | 232 | 232 | 181 | 178 | 178 |
FULL LOAD{LB-FT} | 29.8 | 29.8 | 30 | 36.4 | 36.4 |
NEMA Nominal and Guaranteed Efficiencies are up to 3,300 feet above sea level and 25 ° C ambient
The Above Data Is Typical, Sinewave Power Unless Noted Otherwise | ||
| NIDEC MOTOR CORPORATION | |
Nidec trademarks followed by the ® symbol are registered with the U.S. Patent and Trademark Office. |