MODEL NO.CATALOG NO.PHASETYPEFRAME
 FZ78U14P2GC 3 UTE 56C
ORDER NO. 25904LINE NO. 
MPI:249067
HP: 0.25
POLES:4
VOLTS:575
HZ:60
SERVICE FACTOR:1.25
EFFICIENCY (%): 
S.F.76.9
FULL74
3/473
1/266.8
1/452.2
POWER FACTOR (%): 
S.F.74
FULL67.6
3/458.7
1/247.1
1/432.5
NO LOAD14.4
LOCKED ROTOR70.2
AMPS: 
S.F.0.4
FULL0.4
3/40.3
1/20.3
1/40.3
NO LOAD0.3
LOCKED ROTOR2.4
NEMA CODE LETTERL
NEMA DESIGN LETTERB
FULL LOAD RPM1750
NEMA NOMINAL / EFFICIENCY (%)74
GUARANTEED EFFICIENCY (%)70
MAX KVAR0.3
AMBIENT (°C)40
ALTITUDE (FASL)3300
SAFE STALL TIME-HOT (SEC)30
SOUND PRESSURE (DBA @ 1M)0
TORQUES: 
BREAKDOWN{% F.L.}414
LOCKED ROTOR{% F.L.}295
FULL LOAD{LB-FT}0.7

NEMA Nominal and Guaranteed Efficiencies are up to 3,300 feet above sea level and 25 ° C ambient

The Above Data Is Typical, Sinewave Power Unless Noted Otherwise


 

NIDEC MOTOR CORPORATION
ST. LOUIS, MO

U.S. Motors


            Nidec trademarks followed by the ® symbol are registered with the U.S. Patent and Trademark Office.