MODEL NO.CATALOG NO.PHASETYPEFRAME
 GD418D40P3C 3 CE 364T
ORDER NO. 25146LINE NO. 
MPI:229595
HP: 40
POLES:6
VOLTS:460
HZ:60
SERVICE FACTOR:1.15
EFFICIENCY (%): 
S.F.93.6
FULL94.1
3/494.8
1/294.6
1/492.1
POWER FACTOR (%): 
S.F.85.2
FULL84.7
3/481.9
1/274.1
1/454.2
NO LOAD4.3
LOCKED ROTOR34.4
AMPS: 
S.F.54
FULL47
3/436
1/226.7
1/418.8
NO LOAD15.4
LOCKED ROTOR300.3
NEMA CODE LETTERG
NEMA DESIGN LETTERB
FULL LOAD RPM1190
NEMA NOMINAL / EFFICIENCY (%)94.1
GUARANTEED EFFICIENCY (%)93
MAX KVAR10.4
AMBIENT (°C)40
ALTITUDE (FASL)3300
SAFE STALL TIME-HOT (SEC)30
SOUND PRESSURE (DBA @ 1M)65
TORQUES: 
BREAKDOWN{% F.L.}228
LOCKED ROTOR{% F.L.}153
FULL LOAD{LB-FT}176.6

NEMA Nominal and Guaranteed Efficiencies are up to 3,300 feet above sea level and 25 ° C ambient

The Above Data Is Typical, Sinewave Power Unless Noted Otherwise


 

NIDEC MOTOR CORPORATION
ST. LOUIS, MO

U.S. Motors


            Nidec trademarks followed by the ® symbol are registered with the U.S. Patent and Trademark Office.