MODEL NO. | CATALOG NO. | PHASE | TYPE | FRAME |
GG27 | CD1P2E | 3 | TCE | 143T |
ORDER NO. | 25289 | LINE NO. |
MPI: | 232665 | 232666 | 252352 | 232667 | 232668 |
HP: | 1 | 1 | 1 | 1 | 1 |
POLES: | 4 | 4 | 4 | 4 | 4 |
VOLTS: | 460 | 230 | 208 | 400 | 200 |
HZ: | 60 | 60 | 60 | 50 | 50 |
SERVICE FACTOR: | 1.15 | 1.15 | 1.15 | 1.15 | 1 |
EFFICIENCY (%): | |||||
S.F. | 85.8 | 85.8 | 85.3 | 85.9 | |
FULL | 85.5 | 85.5 | 85.5 | 86.2 | 84.7 |
3/4 | 84.7 | 84.7 | 85.3 | 86.1 | 84.7 |
1/2 | 81.7 | 81.7 | 83.1 | 83.8 | 82.4 |
1/4 | 71.8 | 71.8 | 74.9 | 75.4 | 73.9 |
POWER FACTOR (%): | |||||
S.F. | 76.8 | 76.8 | 81.2 | 79.8 | |
FULL | 73.2 | 73.2 | 78.3 | 76.5 | 76.4 |
3/4 | 64.5 | 64.5 | 70.7 | 68.1 | 68 |
1/2 | 51.4 | 51.4 | 58 | 54.7 | 54.7 |
1/4 | 32.4 | 32.4 | 37.6 | 34.8 | 34.8 |
NO LOAD | 7.9 | 7.9 | 8.2 | 7.7 | 7.7 |
LOCKED ROTOR | 62.5 | 62.5 | 61.1 | 68.5 | 68.5 |
AMPS: | |||||
S.F. | 1.6 | 3.2 | 3.4 | 1.8 | |
FULL | 1.5 | 3 | 3.1 | 1.6 | 3.3 |
3/4 | 1.3 | 2.5 | 2.5 | 1.4 | 2.8 |
1/2 | 1.1 | 2.2 | 2.1 | 1.2 | 2.3 |
1/4 | 1 | 2 | 1.8 | 1 | 2.1 |
NO LOAD | 0.9 | 1.9 | 1.7 | 1 | 2 |
LOCKED ROTOR | 14.7 | 29.3 | 25.9 | 14 | 28 |
NEMA CODE LETTER | N | N | L | L | L |
NEMA DESIGN LETTER | B | B | B | B | B |
FULL LOAD RPM | 1760 | 1760 | 1755 | 1455 | 1455 |
NEMA NOMINAL / EFFICIENCY (%) | 85.5 | 85.5 | 85.5 | 86.2 | 84.7 |
GUARANTEED EFFICIENCY (%) | 82.5 | 82.5 | 82.5 | 82.5 | 81.5 |
MAX KVAR | 0.6 | 0.6 | 0.5 | 0.6 | 0.6 |
AMBIENT (°C) | 40 | 40 | 40 | 40 | 40 |
ALTITUDE (FASL) | 3300 | 3300 | 3300 | 3300 | 3300 |
SAFE STALL TIME-HOT (SEC) | 20 | 20 | 26 | 22 | 22 |
SOUND PRESSURE (DBA @ 1M) | 54 | 0 | 54 | 0 | 50 |
TORQUES: | |||||
BREAKDOWN{% F.L.} | 495 | 495 | 394 | 418 | 464 |
LOCKED ROTOR{% F.L.} | 404 | 404 | 315 | 366 | 366 |
FULL LOAD{LB-FT} | 3 | 3 | 3 | 3.6 | 3.6 |
NEMA Nominal and Guaranteed Efficiencies are up to 3,300 feet above sea level and 25 ° C ambient
The Above Data Is Typical, Sinewave Power Unless Noted Otherwise | ||
| NIDEC MOTOR CORPORATION | |
Nidec trademarks followed by the ® symbol are registered with the U.S. Patent and Trademark Office. |