MODEL NO. | CATALOG NO. | PHASE | TYPE | FRAME |
HA62 | DJ7P3EP | 3 | DE1 | 254JP |
ORDER NO. | 25966 | LINE NO. |
MPI: | 143953 | 143954 | 143956 | 143957 |
HP: | 7.5 | 7.5 | 7.5 | 7.5 |
POLES: | 6 | 6 | 6 | 6 |
VOLTS: | 460 | 230 | 380 | 190 |
HZ: | 60 | 60 | 50 | 50 |
SERVICE FACTOR: | 1.15 | 1.15 | 1.15 | 1.15 |
EFFICIENCY (%): | ||||
S.F. | 90.9 | 90.9 | 88.1 | 88.1 |
FULL | 91 | 91 | 89.2 | 89.2 |
3/4 | 91.7 | 91.7 | 90.8 | 90.8 |
1/2 | 90.8 | 90.8 | 91 | 91 |
1/4 | 85.9 | 85.9 | 87.8 | 87.8 |
POWER FACTOR (%): | ||||
S.F. | 83.1 | 83.1 | 84.8 | 84.8 |
FULL | 81.6 | 81.6 | 84.1 | 84.1 |
3/4 | 76.9 | 76.9 | 80.8 | 80.8 |
1/2 | 66.9 | 66.9 | 72.9 | 72.9 |
1/4 | 45 | 45 | 51.9 | 51.9 |
NO LOAD | 6 | 6 | 5.8 | 5.8 |
LOCKED ROTOR | 45.3 | 45.3 | 48.1 | 48.1 |
AMPS: | ||||
S.F. | 10.7 | 21.4 | 13.1 | 26.2 |
FULL | 9.5 | 18.9 | 11.4 | 22.8 |
3/4 | 7.5 | 14.9 | 8.7 | 17.4 |
1/2 | 5.8 | 11.6 | 6.4 | 12.8 |
1/4 | 4.5 | 9.1 | 4.7 | 9.3 |
NO LOAD | 4.1 | 8.2 | 4 | 8 |
LOCKED ROTOR | 59.7 | 119.5 | 56.7 | 112.3 |
NEMA CODE LETTER | H | H | E | E |
NEMA DESIGN LETTER | B | B | B | B |
FULL LOAD RPM | 1185 | 1185 | 980 | 980 |
NEMA NOMINAL / EFFICIENCY (%) | 91 | 91 | 89.2 | 89.2 |
GUARANTEED EFFICIENCY (%) | 89.5 | 89.5 | 86.5 | 86.5 |
MAX KVAR | 2.8 | 2.8 | 2.2 | 2.2 |
AMBIENT (°C) | 40 | 40 | 40 | 40 |
ALTITUDE (FASL) | 3300 | 3300 | 3300 | 3300 |
SAFE STALL TIME-HOT (SEC) | 30 | 30 | 30 | 30 |
SOUND PRESSURE (DBA @ 1M) | 58 | 58 | 54 | 54 |
TORQUES: | ||||
BREAKDOWN{% F.L.} | 285 | 285 | 223 | 223 |
LOCKED ROTOR{% F.L.} | 199 | 199 | 153 | 153 |
FULL LOAD{LB-FT} | 33.3 | 33.3 | 40.3 | 40.3 |
NEMA Nominal and Guaranteed Efficiencies are up to 3,300 feet above sea level and 25 ° C ambient
The Above Data Is Typical, Sinewave Power Unless Noted Otherwise | ||
| NIDEC MOTOR CORPORATION | |
Nidec trademarks followed by the ® symbol are registered with the U.S. Patent and Trademark Office. |