MODEL NO.CATALOG NO.PHASETYPEFRAME
 HZ63FF125E1GS 3 FR 404TS
ORDER NO. 28233LINE NO. 
MPI:319860
HP: 125
POLES:2
VOLTS:575
HZ:60
SERVICE FACTOR:1.15
EFFICIENCY (%): 
S.F.93.9
FULL94.1
3/494.9
1/294.7
1/492.1
POWER FACTOR (%): 
S.F.90.6
FULL90.8
3/490.2
1/286.6
1/472.3
NO LOAD7.5
LOCKED ROTOR30
AMPS: 
S.F.127
FULL110
3/482
1/257
1/435
NO LOAD22.9
LOCKED ROTOR723
NEMA CODE LETTERG
NEMA DESIGN LETTERB
FULL LOAD RPM3567
NEMA NOMINAL / EFFICIENCY (%)94.1
GUARANTEED EFFICIENCY (%)93
MAX KVAR19.4
AMBIENT (°C)40
ALTITUDE (FASL)3300
SAFE STALL TIME-HOT (SEC)9
SOUND PRESSURE (DBA @ 1M)81
TORQUES: 
BREAKDOWN{% F.L.}300
LOCKED ROTOR{% F.L.}156
FULL LOAD{LB-FT}184.1

NEMA Nominal and Guaranteed Efficiencies are up to 3,300 feet above sea level and 25 ° C ambient

The Above Data Is Typical, Sinewave Power Unless Noted Otherwise


 

NIDEC MOTOR CORPORATION
ST. LOUIS, MO

U.S. Motors


            Nidec trademarks followed by the ® symbol are registered with the U.S. Patent and Trademark Office.