Order Number, Order Type, Line Number: | NA |
Model Number: | |
|
Segment | JDE Level | Description | JDE Return |
Seg. 132 | CTD DATA | Dim. "A"- Rotor Bore | |
Seg. XXX | | Dim. "B"- | |
Seg. 126 | CTD DATA | Dim. "C"- Stator Diameter | |
Seg. 149 | CONNECT | Dim. "LG"- Stack Length + Ducts | |
Seg. 536 | CTD DATA | Stator Die Number | |
|
Stator Core (reference 982692-A) |
|
NOTES:- ALL WELDS MUST BE UNBROKEN.
- .015 MAX GAP BETWEEN LAMINATIONS ON THE STATOR OUTSIDE DIAMETER.
- .030 MAX GAP BETWEEN LAMINATIONS ON THE STATOR INNER BORE.
- STATOR BORE STACK LENGTH TOLERANCE IS .25 INCHES OVER THE NOMINAL DIMENSION.
CAUTION: STACK LAMINATIONS SO THAT INSIDE DIAMETERS ARE ALL CONCENTRIC WITHIN .002 INCHES BURR TO BE ON ONE SIDE.- ROTATE LAMINATIONS DURING STACKING IN 2 TO 3 INCH PACKETS BY 120 DEG. INCREMENTS.
- FUSE WELD IN "E" PLACES TO A MAX. DEPTH OF .125 INCHES.
- * DIM "B" FOR FORMWOUND SLOTS ONLY.
- "B" EQUALS MINIMUM EFFECTIVE SLOT WIDTH FOR ANY 3.5 INCHES OF STACK.
|